FIGURE 4. Narrowband conducted emission limit.
3.4.8 Nuclear hardening. Requirements for nuclear survivability shall be as specified in a separate classified
(confidential) document entitled "Nuclear Survivability Criteria for the Automatic Fire Extinguishing Systems (AFES)"
3.4.9 Ventilation fan. The MSEC shall provide an activation signal to switch on the ventilation fan 8 to 10 s after
activation of the fire extinguishers (see 4.6.3).
3.5 Environmental. The MSEC shall function satisfactorily, evidence no deterioration, and meet the requirements
of 3.4.1 through 3.4.6 during or after, as specified, exposure to the following environments. The MSEC shall produce
15